{"product_id":"ts4-a-2f","title":"Tigo TS4-A-2F | 2 Module Rapid Shutdown","description":"\u003ch1 data-start=\"248\" data-end=\"308\"\u003eTigo TS4-A-2F Dual Module MLPE | Rapid Shutdown Solution\u003c\/h1\u003e\n\u003cp\u003e\u003cstrong\u003eEstimated to ship early November\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"310\" data-end=\"691\"\u003eThe \u003cstrong data-start=\"314\" data-end=\"331\"\u003eTigo TS4-A-2F\u003c\/strong\u003e is a \u003cstrong data-start=\"337\" data-end=\"383\"\u003ecost-effective rapid shutdown device (RSD)\u003c\/strong\u003e engineered for \u003cstrong data-start=\"399\" data-end=\"451\"\u003emodule-level safety and NEC 2017\/2020 compliance\u003c\/strong\u003e. Designed to control two PV modules per unit, the TS4-A-2F helps installers save time and reduce costs by minimizing wiring complexity—offering up to \u003cstrong data-start=\"602\" data-end=\"648\"\u003e16% fewer connections on a 14-panel string\u003c\/strong\u003e compared to single-channel MLPE devices.\u003c\/p\u003e\n\u003cp data-start=\"693\" data-end=\"1047\"\u003eBacked by \u003cstrong data-start=\"703\" data-end=\"732\"\u003eIEC and UL certifications\u003c\/strong\u003e and \u003cstrong data-start=\"737\" data-end=\"760\"\u003eUL PVRSS compliance\u003c\/strong\u003e with the industry’s widest network of inverters, this rapid shutdown unit ensures global acceptance and seamless integration. Many inverter brands already feature built-in RSS transmitters, allowing for \u003cstrong data-start=\"964\" data-end=\"999\"\u003eplug-and-play PLC communication\u003c\/strong\u003e that simplifies and accelerates installation.\u003c\/p\u003e\n\u003chr data-start=\"1049\" data-end=\"1052\"\u003e\n\u003ch2 data-start=\"1054\" data-end=\"1082\"\u003eKey Features \u0026amp; Benefits\u003c\/h2\u003e\n\u003cul data-start=\"1084\" data-end=\"1930\"\u003e\n\u003cli data-start=\"1084\" data-end=\"1207\"\u003e\n\u003cp data-start=\"1086\" data-end=\"1207\"\u003e\u003cstrong data-start=\"1086\" data-end=\"1112\"\u003eDual-Module Connection\u003c\/strong\u003e – One MLPE supports \u003cstrong data-start=\"1133\" data-end=\"1160\"\u003e2 solar panels per unit\u003c\/strong\u003e, reducing labor, hardware, and system costs.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1208\" data-end=\"1354\"\u003e\n\u003cp data-start=\"1210\" data-end=\"1354\"\u003e\u003cstrong data-start=\"1210\" data-end=\"1233\"\u003eHigh Power Capacity\u003c\/strong\u003e – Handles up to \u003cstrong data-start=\"1250\" data-end=\"1307\"\u003e1000W (500W per channel), 16–80V, and 15A per channel\u003c\/strong\u003e, suitable for today’s high-power PV modules.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1355\" data-end=\"1484\"\u003e\n\u003cp data-start=\"1357\" data-end=\"1484\"\u003e\u003cstrong data-start=\"1357\" data-end=\"1382\"\u003eCertified \u0026amp; Compliant\u003c\/strong\u003e – Meets \u003cstrong data-start=\"1391\" data-end=\"1423\"\u003eNEC 2017\/2020 rapid shutdown\u003c\/strong\u003e requirements, IEC \u0026amp; UL certified, and \u003cstrong data-start=\"1462\" data-end=\"1481\"\u003eUL PVRSS listed\u003c\/strong\u003e.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1485\" data-end=\"1594\"\u003e\n\u003cp data-start=\"1487\" data-end=\"1594\"\u003e\u003cstrong data-start=\"1487\" data-end=\"1518\"\u003eWide Inverter Compatibility\u003c\/strong\u003e – Approved with \u003cstrong data-start=\"1535\" data-end=\"1560\"\u003ehundreds of inverters\u003c\/strong\u003e for maximum design flexibility.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1595\" data-end=\"1735\"\u003e\n\u003cp data-start=\"1597\" data-end=\"1735\"\u003e\u003cstrong data-start=\"1597\" data-end=\"1625\"\u003eFast Plug-and-Play Setup\u003c\/strong\u003e – Communicates via PLC with inverters that include integrated RSS transmitters, reducing installation time.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1736\" data-end=\"1845\"\u003e\n\u003cp data-start=\"1738\" data-end=\"1845\"\u003e\u003cstrong data-start=\"1738\" data-end=\"1767\"\u003eInstaller-Friendly Design\u003c\/strong\u003e – Snaps directly onto the module frame with \u003cstrong data-start=\"1812\" data-end=\"1842\"\u003eno grounding wire required\u003c\/strong\u003e.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1846\" data-end=\"1930\"\u003e\n\u003cp data-start=\"1848\" data-end=\"1930\"\u003e\u003cstrong data-start=\"1848\" data-end=\"1875\"\u003eStandard MC4 Connectors\u003c\/strong\u003e – Streamlined integration with common PV connectors.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1932\" data-end=\"1935\"\u003e\n\u003ch2 data-start=\"1937\" data-end=\"1956\"\u003eSpecifications\u003c\/h2\u003e\n\u003cul data-start=\"1958\" data-end=\"2183\"\u003e\n\u003cli data-start=\"1958\" data-end=\"2006\"\u003e\n\u003cp data-start=\"1960\" data-end=\"2006\"\u003e\u003cstrong data-start=\"1960\" data-end=\"1977\"\u003eConfiguration\u003c\/strong\u003e: 2 PV modules per TS4 unit\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2007\" data-end=\"2050\"\u003e\n\u003cp data-start=\"2009\" data-end=\"2050\"\u003e\u003cstrong data-start=\"2009\" data-end=\"2022\"\u003eMax Power\u003c\/strong\u003e: 1000W (500W per channel)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2051\" data-end=\"2080\"\u003e\n\u003cp data-start=\"2053\" data-end=\"2080\"\u003e\u003cstrong data-start=\"2053\" data-end=\"2070\"\u003eVoltage Range\u003c\/strong\u003e: 16–80V\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2081\" data-end=\"2117\"\u003e\n\u003cp data-start=\"2083\" data-end=\"2117\"\u003e\u003cstrong data-start=\"2083\" data-end=\"2098\"\u003eMax Current\u003c\/strong\u003e: 15A per channel\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2118\" data-end=\"2159\"\u003e\n\u003cp data-start=\"2120\" data-end=\"2159\"\u003e\u003cstrong data-start=\"2120\" data-end=\"2138\"\u003eCertifications\u003c\/strong\u003e: IEC, UL, UL PVRSS\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2160\" data-end=\"2183\"\u003e\n\u003cp data-start=\"2162\" data-end=\"2183\"\u003e\u003cstrong data-start=\"2162\" data-end=\"2176\"\u003eConnectors\u003c\/strong\u003e: MC4\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"2185\" data-end=\"2274\"\u003e⚠ \u003cstrong data-start=\"2187\" data-end=\"2195\"\u003eNote\u003c\/strong\u003e: Requires a \u003cstrong data-start=\"2208\" data-end=\"2257\"\u003eTigo CCA (Cloud Connect Advanced) Transmitter\u003c\/strong\u003e for operation.\u003c\/p\u003e\n\u003chr data-start=\"2276\" data-end=\"2279\"\u003e\n\u003ch2 data-start=\"2281\" data-end=\"2315\"\u003eWhy Choose the Tigo TS4-A-2F?\u003c\/h2\u003e\n\u003cp data-start=\"2317\" data-end=\"2652\"\u003eThe Tigo TS4-A-2F is an ideal choice for \u003cstrong data-start=\"2358\" data-end=\"2424\"\u003eresidential, commercial, and utility-scale solar installations\u003c\/strong\u003e where cost, speed, and compliance matter. By reducing balance-of-system (BOS) costs and simplifying wiring, it provides an efficient solution for meeting \u003cstrong data-start=\"2579\" data-end=\"2606\"\u003erapid shutdown mandates\u003c\/strong\u003e while supporting today’s larger PV modules.\u003c\/p\u003e\n\u003cp data-start=\"2654\" data-end=\"2836\"\u003eWhether you’re an \u003cstrong data-start=\"2672\" data-end=\"2715\"\u003einstaller looking for faster deployment\u003c\/strong\u003e or a \u003cstrong data-start=\"2721\" data-end=\"2772\"\u003esystem owner wanting a reliable safety solution\u003c\/strong\u003e, the TS4-A-2F delivers on performance, compliance, and value.\u003c\/p\u003e","brand":"Tigo","offers":[{"title":"Default Title","offer_id":52439934370067,"sku":"17730331170067","price":52.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0850\/1801\/8067\/files\/65adae0b-5a66-47bb-8b46-7648ca022967__26006.jpg?v=1759417869","url":"https:\/\/portable-sun.com\/products\/ts4-a-2f","provider":"Portable Sun LLC","version":"1.0","type":"link"}